Bulk Policresulen (CAS 9011-02-3): Technical Specifications and Industrial Supply Guide
Product Introduction of Policresulen
Certificates & Quality Assurance (COA / Analytical Standards)
Ensuring batch-to-batch polymer chain consistency, accurate acidity levels, and low residual monomer concentrations is critical when supplying Policresulen for industrial formulation. Our manufacturing operations strictly adhere to ISO 9001 quality management standards.
In-House Quality Control & Testing Protocols
High-Performance Liquid Chromatography (HPLC) & Gel Permeation Chromatography (GPC): Verifies the molecular weight distribution pattern of the polymer chain and ensures residual unreacted formaldehyde and cresol monomers remain strictly below international threshold limits.
Acidimetric Titration: Confirms total acidity and active compound concentration, ensuring exact quantitative alignment with technical specifications.
Heavy Metal & Residue Analysis (ICP-MS): Screened to ensure heavy metal impurities (such as Lead, Arsenic, and Cadmium) meet stringent pharmacopeial raw material standards.
Infrared Spectroscopy (FT-IR): Confirms structural identity against standard reference spectra for the condensation polymer framework.
Regulatory & Technical Documentation Available
Certificate of Analysis (COA): Delivered with every commercial shipment batch.
Safety Data Sheet (SDS / MSDS): Complete GHS-compliant document covering safe chemical handling, storage, and emergency response.
Method of Analysis (MOA): Available upon request for technical verification and quality audits.
Product Packaging
Application of Policresulen
Policresulen raw material is supplied strictly for industrial chemical synthesis, pharmaceutical manufacturing inputs, contract research, and laboratory analytical applications. It is not intended for direct consumer use or unformulated direct applications.
Active Ingredient for Pharmaceutical Formulations: Functions as a key active raw material integrated into industrial manufacturing runs for topical liquids, suppositories, and gel formulations under certified pharmaceutical quality systems.
Custom Synthesis & Polymer Research: Utilized in chemical research laboratories as a functionalized acidic aromatic polymer for studying polyelectrolyte interactions and selective protein binding mechanisms.
Analytical Reference Standard: Employed by testing facilities and university laboratories as a reference standard for chromatography validation and monomer impurity profiling.
Industrial Acidic Catalyst & Intermediate: Applied in specialized chemical processes requiring a stable, high-molecular-weight organic sulfonic acid scaffold.
Related Questions:
Q1: What packaging options are used to handle Policresulen's strong acidity?
Q2: What is the shelf life and storage requirement for bulk shipments?
A: Under recommended storage conditions (sealed in original containers at 15–25°C, protected from light and freezing), Policresulen liquid raw material maintains technical stability for 24 months. Re-testing of acidity and monomer levels is recommended after extended storage periods.
Q3: What documentation accompanies international shipments of Policresulen?
Q4: Can you provide custom concentrations or custom powder drying?
A: Yes. As a direct manufacturer with in-house R&D and pilot plant capabilities, we offer custom concentration adjustments (e.g., 36%, 45%, or 50% solutions) as well as specialized low-moisture powder grades based on your formulation development requirements.
Q5: How can our procurement team request a laboratory sample?
A: Qualified industrial purchasing teams and research laboratories can request a technical sample (e.g., 100g to 1kg) along with its batch-specific COA and SDS by contacting our sales department at sales001@zhishangchemical.com.
Manufacturer of Policresulen
API, usually referring to chemical raw materials, is the active ingredient in chemical drug formulations.
Policresulen Safety Information
For raw material procurement managers and quality control teams receiving chemical shipments of Policresulen, validating product integrity upon arrival is a critical quality step. We recommend the following rapid verification workflow:
Visual & Color Assessment: Liquid-grade Policresulen should appear as a clear, dark reddish-brown to brown liquid without phase separation, precipitation, or suspended particulate matter.
Specific Gravity / Density Measurement: For 50% aqueous solution grades, verify that the density at 20°C falls within the standard range ($1.25 – 1.32 \text{ g/cm}^3$).
Solubility & Clarity Check: When diluted with deionized water, the resulting solution must remain completely clear and transparent without turbidity or oil-like surface film.
Packaging Integrity Inspection: Due to the strongly acidic nature of Policresulen, verify that all inner container seals, fluorine-lined polyethylene drums, or acid-resistant plastic containers remain undamaged, leak-free, and sealed under inert conditions.
OrganicIntermediate is a professional foreign trade enterprise specializing in chemical raw materials. Upholding people-oriented values and cooperating with reliable manufacturers, we aim to become the world’s most trusted chemical supplier. Our production plant is located 50 meters south of the intersection of North Ring Road and 13th Road, Chenwang Street, Juancheng County, Heze City, Shandong Province. Our R&D laboratory is situated at R&D Base : F5, Yinfeng Biomedical City, Free Trade Zone, Jinan, Shandong. Integrating R&D and production, we strictly control product quality. With stable supply and sincere service, we welcome global customers for consultation and procurement.
Our Laboratory
Our Factory
Professional service
Related Products
This article was written by William, the chief chemist of Shandong Zhishang New Materials Co., Ltd.
Pubchem-Policresulen