Bulk Ruxolitinib Powder (CAS 941678-49-5) Manufacturer & Factory Supplier | >99% Purity
CAS 941678-49-5 | Ruxolitinib
| CAS No: | 941678-49-5 |
| Formula: | C17H18N6 |
| EINECS: | 1312995-182-4 |
| Stock Availability: | In stock |
| Brand Name: | Zhishang New Materials |
| Origin: | China |
Product Details of Ruxolitinib
Quality Certificates & Analytical Verification (COA / Standards)
Batch-to-batch reproducibility is fundamental when supplying high-value organic intermediates to international research facilities and pharmaceutical manufacturing sites. Our manufacturing unit operates under ISO 9001 certified quality control systems.
In-House Testing Protocols & Quality Metrics
High-Performance Liquid Chromatography (HPLC): Verifies chemical purity thresholds exceed 99.0%, ensuring individual organic impurities are restricted below strict industrial limits ($< 0.10\%$).
Chiral HPLC Analysis: Confirms precise stereochemical integrity, guaranteeing that the unwanted $(S)$-enantiomer is kept below negligible detection levels.
Proton Nuclear Magnetic Resonance ($^1\text{H-NMR}$) & Mass Spectrometry (MS): Confirms structural identity and validates the exact molecular weight.
Loss on Drying (LOD) & Heavy Metals Analysis: Tested via ICP-MS to guarantee heavy metals and residual solvents meet rigorous international chemical safety standards.
Standard Documentation Package
Certificate of Analysis (COA): Dispatched with every commercial shipment batch.
Safety Data Sheet (SDS / MSDS): Fully GHS-compliant handling and safety protocols.
Method of Analysis (MOA) & Spectroscopic Spectra: Provided upon request for client verification audits.
Product Self-Inspection & Quality Verification Guide
For quality control technicians and procurement managers receiving commercial packaging or analytical samples of Ruxolitinib, confirming raw material integrity upon arrival is a critical quality assurance step. We recommend the following rapid verification workflow:
Visual & Crystalline Inspection: The product should appear as a uniform, fine, off-white to pale yellow crystalline powder. It must be free of physical clumping, moisture-induced discoloration, or visible particulate contaminants.
Solubility & Clarity Testing: Dissolve a trial sample in anhydrous DMSO at room temperature. The resulting solution should remain completely clear, transparent, and free of undissolved particulate matter.
Melting Range Audit: Verify that the melting point corresponds strictly to the technical specification range (84°C – 89°C). A broad or depressed melting point indicates moisture absorption or organic impurity contamination.
Packaging Seal Audit: Check that multi-layer barrier seals remain fully intact. Because cold-storage compounds can attract condensation upon exposure to ambient room air, inner PE bag seals must remain completely airtight.
Technical Uses & Research Applications
Ruxolitinib is supplied exclusively for industrial synthesis, research laboratory development, analytical reference testing, and contract chemical manufacturing. It is strictly a raw intermediate material and chemical reagent.
Pharmaceutical Intermediate: Functions as an essential core molecule or building block in the synthesis and formulation testing of advanced small-molecule derivatives.
Biochemical Pathway Research Tool: Widely utilized in academic and laboratory research to explore cell-signaling cascades, specifically kinase receptor pathways (JAK1/JAK2 signaling networks) in biological model systems.
Analytical Reference Control: Applied by analytical testing laboratories as a reference standard for method validation, HPLC calibration, and impurity profiling in chemical manufacturing.
Contract Synthesis & Scale-Up Projects: Integrated by CDMO/CRO organizations into custom synthetic pipelines requiring high-purity chiral building blocks.
Related Questions:
Q1: Does CAS 941678-49-5 consist of phosphate components? Just how to align it when calculating the feeding ratio?
Answer: CAS 941678-49-5 strictly corresponds to the free base of Ruxolitinib. Preferably, it does not contain included phosphate or other acid ions, and differs from the salt type in regards to structure. If your study method is based upon Ruxolitinib Phosphate (CAS 1092939-17-7), a conversion is necessary. The molecular weight of the free base is approximately 306.37, while the molecular weight of phosphate (monophosphate) given in common literary works is around 404.4. Basically, around 100mg of free base is equivalent to around 132mg of phosphate (calculated as monophosphate) in terms of equimolar compound (calculated based on the moms and dad core of Ruxolitinib). When acquiring, it is advised to verify the requirements of the experimental system for pH and solubility to choose the preferable chemical type.
Q2: Exactly how do you confirm that the product is in (3R) arrangement rather than racemic type?
Response: Chiral purity is the core of the high quality of ruxolitinib. We mainly confirm it in 2 ways: First, chiral HPLC detection, making use of chiral chromatography columns to divide the (3R) and (FOUR) isomers and calculate the enantiomeric unwanted (ee%), and we will certainly agree on the ee% target with the customer in the high quality criterion (e.g., ≥ 99.0% or higher, depending on the application). Second, we discover the particular turning and suggest the discovery concentration, solvent, and temperature in the COA. We can give chromatograms of contrast samples as called for to sustain the verification of configurational uniformity.
Q3: Pertaining to contamination control, specifically for procedure contaminations that may have potential sensitivity, what methods do you have in area?
Solution: Our contamination control strategy is based on relevant standards such as ICH Q3A/Q3B and M7. For ruxolitinib, we concentrate on checking the recurring pyrimidine intermediates involved in the synthesis path and the spin-offs produced during the intro of the propionitrile side chain. With high-sensitivity HPLC-UV or LC-MS methods, we control the private contaminations and overall contaminations within the mutually agreed restrictions (for instance, referring to usual indicators such as 0.1% or 0.5%, depending on the intended use and compliance requirements). Possible recurring solvents (such as acetonitrile, methanol, toluene, and so on) are quantitatively found by gas chromatography (GC) to straighten with the limit needs of ICH Q3C.
Q4: How does the raw product dissolve in different solvents? Exists any type of recommendation for preparing the mommy remedy?
Answer: Ruxolitinib free base is a nitrogen-containing heterocyclic small molecule, and organic solvent systems are typically chosen for its formula. According to usual expressions in released technical materials, it can be formulated right into mg/mL-level supply remedies in DMSO (for instance, some released technological recommendations discuss the expediency of formulation at details concentrations, such as the 10 mg/mL degree), and suggest that its solubility in liquid systems is fairly restricted; it likewise has certain solubility in solvents such as ethanol and DMF. The solution and storage techniques are recommended to follow your interior SOP; in several laboratory methods, aliquoting, security from light, low-temperature storage space, and lessening repeated freeze-thaw cycles and extended direct exposure to high moisture are adopted.
Q5: What certain things are included in the COA (Certificate of Analysis) you offer? Do you support third-party retesting?
Answer: The standard COA typically includes: appearance summary, identification (1H-NMR, IR, LC-MS, etc), purity (HPLC), related materials, residual solvents (GC), and assay (generally calculated on a completely dry basis). If required by the client, we can additionally incorporate things such as chiral pureness (Chiral-HPLC), dampness (Karl Fischer technique), and essential impurities into the launch criteria. We support customers in leaving third-party testing organizations for retesting. If the test results drift within a sensible experimental mistake variety, we have a top quality argument handling process in place, consisting of sampling, retention for retesting, and quality traceability.
Q6: Exactly how steady is the raw product? Does it call for special temperature level control throughout long-distance worldwide transportation?
Solution: The security efficiency of ruxolitinib might vary under different chemical types, solid states, and packaging conditions. Openly offered information on long-lasting security likewise differs depending on provider standards. For example, some research-grade products specify storage space at -20 ° C for the “phosphate” form and provide reference information on multi-year stability; others advise against duplicated freeze-thaw cycles. For basic material purchase, it is more sensible to establish transportation and storage methods based on actual batch COA, security data (if readily available), transportation season, and path. For worldwide transport, secured, light-protected, and moisture-proof product packaging can be made use of; in case of high temperature seasons or inner client requirements, temperature-controlled transport options can additionally be reviewed.
Q7: What is your production scale? Can you ensure secure supply from R&D degree to tonnage level?
Solution: We can provide supply ranging from gram to kilogram levels, and upon explanation of need, we can assess production scheduling and confirmation plans for bigger scales. For jobs requiring long-lasting supply, we normally prioritize discussions on essential quality characteristics of the synthesis route, danger points during scaling up (such as chiral retention, trends in relevant materials, and uniformity of solid state morphology), along with adjustment monitoring systems, in order to boost the predictability of supply and reduce uncertainties emerging from transitions between various phases.
Q8: Regarding packaging and internal product packaging materials, just how do you prevent the products from being infected or broken down once again?
Answer: We take on an internal product packaging system that satisfies the usual requirements of the pharmaceutical industry. The initial layer is a pharmaceutical-grade low-density polyethylene (LDPE) bag, the 2nd layer is a light-proof aluminum foil bag, and the outer layer is a high-density polyethylene drum or cardboard drum. For materials vulnerable to producing static electricity, we add anti-static packaging. All product packaging processes are finished in a regulated setting, and cleansing and cross-contamination prevention monitoring are executed to decrease the danger of introducing ecological fibers or steel bits throughout the loading process.
Q9: Can you provide custom particle sizing or specific micronization for this raw material?
A: Yes. Our in-house chemical processing facilities offer custom particle size distribution (PSD) adjustments and micronization upon technical request to meet specific bulk density requirements.
Q10: How can procurement teams request a sample and technical quotation?
A: You can request a technical sample and current batch COA directly through our technical sales department by emailing sales001@zhishangchemical.com or submitting an inquiry via our website contact form.
Ruxolitinib of Zhishang New Materials meets international standards. If you have any other questions or would like to place an order, please feel free to contact us at any time.
Our Advantages The procurement of pharmaceutical intermediates usually not only considers the “total purity“, but also the “factors impacting downstream processes“.
When communicating with customers, we usually focus on the following dimensions to facilitate the formation of practical acceptance and reordering standards:
Batch consistency: Under the same specifications, the assay and key impurities of different batches should show minimal variation.
Key impurities can be explained and traced: the source of impurities and their relevance to the process step must be clearly stated by the supply side.
Drying and moisture control: Reducing the fluctuations caused by moisture is usually a basic requirement for raw materials with chlorinated methyl structures.
Packaging and transportation stability: Avoid risks caused by compression, moisture, foreign odors, or cross-contamination.
Document and communication efficiency: COA information is complete and batch information is clear, facilitating collaboration among procurement, warehousing, and research and development.
We prefer to make our products into ‘long-term cooperative intermediates‘ rather than just completing one delivery.
API, usually referring to chemical raw materials, is the active ingredient in chemical drug formulations.
Properties of [Ruxolitinib CAS 941678-49-5]
| Melting point | 84-89°C |
| density | 1.40 |
| storage temp. | -20° |
| solubility | Soluble in DMSO (up to 28 mg/ml) or in Ethanol (up to 15 mg/ml with warming). |
| form | White powder. |
| pka | 11.63±0.50(Predicted) |
| color | White |
Our Laboratory
Our Factory
Professional service
Related Products
This article was written by William, the chief chemist of Shandong Zhishang New Materials Co., Ltd.
Pubchem-Ruxolitinib






